The QC1904 is a passive probe designed to work with any oscilloscope featuring a standard BNC input for measurement of intermediate and low frequency signals.
This quality probe set consists of a 1.2m quality cord terminated at one end with a moulded-on stainless steel BNC connector and 1 x, 10x attenuator probe at the other end. An earthing lead 120mm long with alligator clip to connect to the probe at the other end is provided.
Input Voltage: x1:<200V DC +Peak AC ; x10: <600V DC +Peak AC
Bandwidth: x1 DC-6MHz, x10 DC to 100MHz
Attenuation ratio: 1X / 10X
Input impedance: x1: 85pF-115pF; x10:18.5pF-22.5pF
Not to be used for EHT (Extra High Tension) voltage.